Overview
The 150kVA Cummins Generator (150千伏安康明斯发电机) is a premium power generation solution designed for businesses that demand uncompromising reliability and performance. Featuring a heavy-duty Cummins diesel engine coupled with a high-efficiency alternator, this generator delivers consistent power output for both standby emergency use and prime power applications.
This generator set is engineered for the global market with compliance to ISO 8528 standards, ensuring world-class quality in design, manufacturing, and testing. Its proven track record in demanding environments makes it a trusted choice for critical infrastructure worldwide.
Applications
The 150kVA Cummins Generator is ideally suited for:
• Hospitals & Medical Centers: Life-critical equipment and emergency systems
• Data Centers & Server Rooms: IT infrastructure requiring zero-downtime backup
• Hotels & Hospitality: Guest comfort systems including HVAC and elevators
• Manufacturing: Production lines and precision machinery
• Commercial Buildings: Lighting, security, and fire safety systems
• Agriculture & Farming: Irrigation pumps, grain dryers, and processing equipment
Key Features & Benefits
• Premium Cummins Engine: Industrial-grade 6-cylinder turbocharged diesel engine
• Excellent Fuel Economy: Optimized fuel injection reduces operating costs
• Advanced Control System: Deep Sea or ComAp smart controller with LCD display
• Brushless Alternator: Stamford-type alternator ensuring voltage stability
• All-Copper Windings: High-grade copper windings for superior conductivity and durability
• Heavy-Duty Base Frame: Integrated fuel tank with level gauge and drain valve
• Multiple Protection Functions: Low oil pressure, high water temperature, overspeed, overload protection
Technical Specifications
| Parameter | Details |
|---|---|
| Model | 150kVA Cummins Generator Set |
| Prime Power | 150kVA / 120kW (50Hz) |
| Standby Power | 165kVA / 132kW (50Hz) |
| Voltage | 400/230V 3-phase 4-wire |
| Power Factor | 0.8 lagging |
| Frequency | 50Hz |
| Engine Brand | Cummins (original) |
| Cylinder Arrangement | 6-cylinder in-line, vertical |
| Aspiration | Turbocharged, charge-air cooled |
| Compression Ratio | ~16:1 |
| Governor Type | Electronic ECU |
| Cooling System | Forced circulation water-cooled |
| Total Coolant Capacity | ~25-35 liters |
| Lube Oil Capacity | ~28-38 liters |
| Fuel Consumption at 100% load | ~33 L/hr |
| Fuel Tank Capacity | 350L standard |
| Runtime at 75% load | ~10 hours |
| Alternator Type | Brushless, self-exciting |
| Insulation Class | H-class |
| Protection Grade | IP23 |
| Starting Motor | 24V DC electric starter |
| Battery Charging Alternator | Included (standard) |
| Noise Level (Open type) | ≈98-102 dB(a) @ 7m |
| Noise Level (Silent type) | ≈72-75 dB(a) @ 7m |
| Dimensions Open (LxWxH) | 2800 x 1000 x 1650mm |
| Dimensions Silent (LxWxH) | 4200 x 1400 x 2200mm |
| Dry Weight (Open) | 1900kg approx. |
| Dry Weight (Silent) | 2600kg approx. |
Why Choose Our 150kVA Cummins Generator?
Our 150kVA Cummins Generators are built with original Cummins engines sourced through authorized channels. Each unit comes with full documentation including engine data sheet, alternator test report, material certificates, and operation manuals. We provide comprehensive warranty coverage backed by our experienced service team.
We understand that every project has unique requirements. That’s why we offer customizable options such as trailer-mounted configuration, dual-frequency capability (50/60Hz), Arctic package for extreme cold conditions, and corrosion-resistant coating for marine or coastal environments. Our engineers work closely with clients to deliver tailored solutions.
Frequently Asked Questions (FAQ)
- What is the difference between prime power and standby power?
- Prime power is the continuous output the generator can deliver for unlimited hours per year. Standby power is the maximum output available during utility power outages, typically limited to 200-500 hours per year. The 150kVA model offers 150kVA prime and 165kVA standby.
- Can I install the generator outdoors without a canopy?
- Yes, open-type generators can be installed outdoors if housed within a purpose-built plant room or weather shelter. For direct outdoor installation, we strongly recommend the silent/canopy type which provides weather protection and noise reduction.
- What kind of fuel should I use?
- We recommend using high-quality diesel fuel meeting BS2869 / ASTM D975 standards. For optimal engine longevity, use ultra-low-sulfur diesel (ULSD) with sulfur content below 15ppm. Avoid using biodiesel blends exceeding B5 without consulting the manufacturer.
- How do I perform routine maintenance?
- Routine maintenance includes daily checks of coolant/oil levels, weekly inspection of belts and hoses, monthly battery condition check, and scheduled service at 250-hour intervals (oil/filter change), 500-hour intervals (fuel filter replacement), and annual comprehensive inspection.
- Can you provide customized control panel configurations?
- Yes, we can configure the control panel with additional features including remote monitoring via GSM/4G, AMF (Auto Mains Failure) functionality, smart grid synchronization, and integration with building management systems (BMS). Please discuss your requirements with our sales engineering team.
Inquire About Our 150kVA Cummins Generator Today
Contact us for pricing, availability, technical specifications, and delivery options for your next power generation project.